ANALISIS PENGARUH KUAT ARUS LISTRIK TERHADAP HASIL PENGELASAN SMAW MATERIAL ST 37 DENGAN ELEKTRODA LOW HIDROGEN PADA PENGUJIAN VISUAL, RADIOGRAFI, STRUKTUR MAKRO DAN MIKRO
Abstract
Mateial ST 37 merupakan baja karbon rendah yang banyak digunakan untuk konstruksi, salah satu proses penyambungan yang sering dilakukan ialah proses pengelasan. Penelitian ini bertujuan untuk mencari dan menentukan kuat arus yang menghasilkan pengelasan paling baik pada proses SMAW posisi 3G dengan tebal 10 mm. Proses penelitian yang dilakukan meliputi pengujian visual inspection, penetrant test, radiografi, struktur makro dan mikro yang telah dilakukan. Hasil penelitian menunjukan bahwa kuat arus pengelasan adalah sebesar root 70 ampere, fill 100 ampere, dan capping 100 ampere. Kuat arus yang digunakan pada sample A berkategori kecil, pada sample B berkategori sedang dan sample C berkategori besar. Pada hasil pengujian visual, penetrant test dan radiografi, spesimen B dinyatakan accepted sedangkan A dan C dinyatakan tidak sesuai dengan kriteria standard sehingga dinyatakan rejected. Pada pengujian struktur makro B memiliki hasil yang paling baik jika dibandingkan spesimen A dan C, dimana spesimen A terdapat cacat slag inclusion pada internal pengelasan, sedangkan specimen C terlihat daerah (Heat effected Zone) HAZ yang lebar jika dibandingkan dengan spesimen A dan B. Hasil pengujian struktur mikro menunjukkan bahwa jenis struktur mikro yang muncul pada spesimen A, B dan C adalah ferrite dan pearlite. Pada spesimen A daerah HAZ terlihat pearlite dan ferit Widmanstatten yang memiliki ukuran butiran besar, dengan orientasi arah yang hampir sama, sehingga memudahkan terjadinya perambatan retak. sedangkan pada spesimen B dan C daerah HAZ terlihat pearlite dan acicular ferit dengan butiran yang halus dan mempunyai ketangguhan lebih tinggi dibanding strutur mikro yang lain.
Kata kunci: visual inspection, penetrant test, radiografi, struktur makro, struktur mikro, pengelasan, SMAW
ANALYSIS OF THE EFFECT ELECTRICAL CURRENT STRENGTH ON THE RESULTS OF ST 37 SMAW MATERIAL USING LOW HYDROGEN ELECTRODES IN VISUAL, RADIOGRAPHY, MACRO AND MICRO STRUCTURES
ST 37 material is a low carbon steel that is widely used for construction. One of the connection processes that is often done is the welding process. This research is intended to find the electrical current that produces the best welding in the SMAW process on 3G position with a thickness of 10 mm based on visual inspection tests, penetrant tests, radiographic tests, macro and micro structures that have been done. The results shows that the electrical current is 70 amperes root, 100 amperes fill, and 100 amperes capping. The current strength used in sample A is in the small category, in sample B it is in the medium category and the sample C is in the large category. Based on the results of visual tests, penetrant tests and radiographic tests, specimen B status was "accepted" while A and C were not in accordance with standard criteria so their status was "rejected". In the macro structure test, specimen B has the best results when compared to specimens A and C. where specimen A has a slag inclusion defect in internal welding, while specimen C shows a wide HAZ when compared to specimens A and B. The microstructure test shows that microstructure types that appear in specimens A, B and C are ferrite and pearlite. In specimen A, the HAZ shows pearlite and Widmanstatten ferrite that has large grain size with almost the same orientation, that lets a crack propagation occur easily. Whereas in specimens B and C, the HAZ shows pearlite and acicular ferrite with fine grains which have higher toughness compared to other micro structure.
Keywords: visual inspection, penetrant test, radiography test, macro structure, micro structure, welding, SMAW
Full Text:
PDFReferences
S. Widharto “Welding Inspection” Mitra Wacana Media, (2013): 9-10
Winarto, The Japan Welding Society, Asosiasi Pengelasan Indonesia. “TEKNOLOGI PENGELASAN”, The Japan Welding Society, (2010): 93
Abson, D. J. dan Pargeter, R. J., 1986, Factors Influencing Strength, “Microstructure and Toughness of as Deposited Manual Metal Arc Welds Deposited Manual Metal Arc Welds Suitable for CMn Steel Fabrications, International Metal Reviews”, vol. 31, No. 4, 141-193
Refbacks
- There are currently no refbacks.