KARAKTERISTIK KURVA KECEPATAN TORSI DAN FAKTOR KERJA PROTOTYPE MESIN LISTRIK AC DINAMIS DAN STATIS DENGAN PEMODELAN RANGKAIAN EKIVALEN

Zainal Abidin, Adam Adam, Suhardiman Suhardiman

Abstract


Dynamic and static AC electric machines can be modeled with equivalent circuits for the purpose of analyzing the characteristics of dynamic and static AC electric machines after their parameter values are known. Methodology to determine the value of equivalent circuit parameters by carrying out no-load testing and short circuit testing. There is a difference in value between dynamic and static AC electric machines with the prototype. The difference in the torque speed curve of the AC electrical engine with a prototype induction electric motor 1,1 kW type squirrel cage rotor, namely Tstart = 0,6 Nm, Ts-max = - 0,23 and Tmax = 3,1N.m, and factors work of static AC electrical machines with 5kVA transformer prototypes, namely pf 0.75 and pf 0.65 in terms of the working voltage side of the secondary coil, namely 1.7V and -1.4 V.


Full Text:

PDF

References


Krause, P. C.; Wasynczuk, O.; Sudhoff, S. D. – “Analysis of Electrical Machinery”.IEEE Press, IEEE, Inc., New York, N.Y.

IEEE Std. 112-1978. “IEEE Standard Test Procedure for Polyphase Induction Motors and Generators”., IEEE, Inc., New York, N.Y.

IEEE St. 112-1996: “IEEE Standard Test Procedure for Induction machines”.IEEE, Inc., New York, N.Y.

G.R. Slemon, “Modeling of Induction Machines for Electric Drives”, IEEE Trans. on Ind. Applications,25.6 (1989): 26-31.

Standard IEC 60034-2-1, “Standard Methods for Determining Losses and Efficiency from test Electrical Machines”, (2008).

A.F.L. Nogueira“Calculation Of Power Transformers Equivalent Circuit Parameters Using Numerical Field Solutions”IJRRAS,17.1, (2013):19-26.

J. Kyncl, A. Hariram, Z. Novák, “ Equivalent Circuit Model for a Single Phase Transformer” Czech Technical University Prague, Czech Republic kyncl, hariradi,2013

J. Baraniak, K. Pachowicz, A. Nafalski, H. Considine and Z. Nedic, “Determination of parameters of an equivalent circuit of a single-phase transformer using a remote laboratory“, World Transactions on Engineering and Technology Education, 14.4 (2016): 445-450

T.A. Saandy, M. Rakotomalala, S. Mze, A. F. Toro, A. Jaomiary, “Analytical DeterminingOf The Steinmetz Equivalent Diagram Elements Of Single-Phase Transformer“ International Journal Of Scientific & Technology Research, 4.12(2015): 382-389

R. Gouws and O. Dobzhanskyi,” Efficiency analysis of a three-phase power transformer”, IEEE Transactions On Instrumentation And Measurement,56.1 (2007): 61-65.

Aeso,Transformer Modelling Guide, Version 2, (2014).


Refbacks